Process level and pressure measurement
Click here for an Advanced Product Search
Call our sales team on +44 (0) 1444 870055
or email us info@uk.vega.com
VEGAPULS Radar non-contact liquid & solids level measurement VEGAFLEX Guided Microwave liquid & solids level measurement, interface level measurement & switching VEGASON Ultrasonic non-contact liquid & solids level measurement VEGACAP Capacitive liquid and solid Level measurement, interface and switching VEGABAR/WELL Hydrostatic level and pressure measurement VEGA Ohmart Nucleonic non-contact liquid & solids level measurement, liquid & solids level switching, interface measurement & switching, density VEGAVIB/WAVE solids level switching and detection of solids interface in liquid VEGASWING liquid level switching VEGAKON Conductive liquid level switching VEGADIF Differential Pressure VEGACOMMS Digital communications for the plant, office, network and internet
Vega News & Events
Industry Technologies
Vega Case Studies
Vega Product Downloads
Vega Job Vacancies
Vega Services & Support
About Vega UK
Contact Vega
www.vegacontrols.co.uk
VEGA UK Process level & pressure instrumentation specialists

Principles of Good Measurement: Density

Posted on 16/04/08, under Dataware, Density, Hydrostatic, Information, Nucleonics, Principles of Good Measurement · RSS · No Comments

 

DENSITY 

densityicon Principles of Good Measurement: Densitydensityicon Principles of Good Measurement: Densitydensityicon Principles of Good Measurement: Densitydensityicon Principles of Good Measurement: Density

If there are changing weights, for a fixed volume, then density measurement is what you need. This will depend on the industry, application and product requirements, for example if you need to reduce the water content to increase concentration, or add heavier solids to the liquid to produce slurry, then this will change the density of the product you want to measure.

 Principles of Good Measurement: Density

Instruments that measure density work by either measuring the weight of an known quantity, or by how the signal conveys the weight – the less of a signal, the more dense, or the more of a signal would be less dense. Obviously, you would need to understand this signal, and automate the process, so you don’t have to sit there and watch it 24/7. These measurements will often ensure the quality of your product.

This measurement principle is widely used for detecting changes in switching and measuring density itself. VEGA have a range of instruments, with different techniques, that detect the differences in density either at a switch point, or as a continuous measurement. These instruments are listed below:

Hydrostatic – VEGABAR/WELL Range

Nucleonic – VEGA OHMART Range

Digital Communications – DATAWARE

Principles of Good Measurement: Level Switching

Posted on 15/04/08, under Capacitive, Conductive, Dataware, Information, Level Switching, Nucleonics, Principles of Good Measurement, Vibration Measurement Liquid Switches, Vibration Measurement Solid Switches · RSS · No Comments

 

LEVEL SWITCHING 

switchicon Principles of Good Measurement: Level Switchingswitchicon Principles of Good Measurement: Level Switchingswitchicon Principles of Good Measurement: Level Switching

Another important control to have in place, for every industry, is the knowledge of when to start and when to stop a process.  If you are emptying, filling, controlling or protecting processes, then you need a reliable and secure level switching solution. 

 Obviously having these switching systems in place is paramount, as any failures, or unnoticed failures, in the aforementioned processes (emptying, filling, controlling and protecting) will cost valuable money and even in some cases affect the environment. 

liquidswitch Principles of Good Measurement: Level Switching

 It is very important for the correct level switching instrument to be chosen, as there will be a few factors that will influence what switching system you require, like whether there are chemicals involved in the process, or whether it’s a liquids or solids application.   Once again, other considerations in your choice of level switch instrument will include whether there are high pressures, temperatures, build up, foam, dust, vapours, or stirrers. 

VEGA Instruments that fulfil the measuring principle of level switching:

 

Capacitive – VEGACAP Range

Nucleonic – VEGA OHMART Range

Vibration Solids – VEGAVIB Range

Vibration Liquids – VEGASWING Range

Conductive – VEGA Conductivity Range

Digital Communications – DATAWARE

Principles of Good Measurement: Level Measurement

Posted on 14/04/08, under Capacitive, Dataware, Hydrostatic, Information, Level Measurement, Nucleonics, Pressure Measurement, Principles of Good Measurement, Ultrasonic · RSS · No Comments

 

 

LEVEL MEASUREMENT

 

levelicons f2 Principles of Good Measurement: Level Measurementlevelicons f2 Principles of Good Measurement: Level Measurementlevelicons f2 Principles of Good Measurement: Level Measurement 

 

One of the most universal measurements needed in almost (if not every) industry is the knowledge of how much you have. This information is needed for storage purposes, controlling processes, or just needing to know how much finished stock is available.  I think you will agree, that every business should be of the numbers and information about their stock, whether it’s stock that needs to be made into something else, or knowing how much you have available to sell.

 

levelinterfacepic Principles of Good Measurement: Level Measurement

 

There are a number of other reasons, as to why this knowledge is important, such as quality, safety, economics or productivity, so having reliable, accurate and automated information on hand, is essential for modern day manufacturing efficiency. 

 

To have this required efficiency in level measurement, the selection of the correct sensor must be made, depending on what your application or product is.   Aspects like physical and chemical attributes of the product must be considered, also high temperatures, pressures will impact on the choice of sensor, especially when there are any kinds of vapour, foam, dust, static etc. involved in the processes

 

The following VEGA Ranges will help you with your level measurement requirements:

 

Radar – VEGAPULS Range

Guided Microwave – VEGAFLEX Range

Ultrasonic – VEGASON Range

Capacitive – VEGACAP Range

Hydrostatic – VEGABAR/WELL Range

Nucleonic – VEGA OHMART Range

Process Pressure – VEGABAR Range

Differential Pressure – VEGADIF Range

Digital Communications – DATAWARE

LATEST PRESS RELEASE: Flush pressure transmitter, buy on-line, 2 day delivery

Posted on 09/04/08, under About VEGA, Hydrostatic, Information, pressure, Pressure Measurement, VEGA Product News · RSS · No Comments

f bars16 e2xv 150 LATEST PRESS RELEASE: Flush pressure transmitter, buy on line, 2 day delivery 

 Amongst the range of level instruments and controls available to buy on-line at the new VEGA e-store, vega-line.co.uk, is the new compact flush-mount hydrostatic level and pressure transmitter VEGABAR S16. At the web shop customers can place an order today and pay a low, fixed price for next day despatch and delivery in 48hrs.

VEGABAR S16 has Tri-clamp or DIN 11851 fittings for hygienic mounting, with IP65 ingress rating and an all stainless steel compact body. Electrical connections are DIN or M12, the transmitter has an ultra-high purity, flush CERTEC Ceramic diaphragm for ultimate performance, strength and process compatibility. Measuring ranges start from 0-0.1bar up to 10 bar gauge, (absolute is an option) and up to 100 times overpressure resistance.

For convenience, accessories also available include welding sockets and mounting brackets. The complete selection of competitively priced, quick delivery level, pressure and signal conditioning devices are at www.vega-line.co.uk.

Contact: 

Doug Anderson
VEGA Controls Ltd
Kendal House, Victoria Way
West Sussex
RH15 9NF 

E-Mail: info@uk.vega.com
Web: www.vegacontrols.co.uk
Tel   +44 1444 870055
Fax   +44 1444 870080

VEGA TDR gets remote housing

Posted on 02/04/08, under Guided Microwave TDR, Information, VEGA Product News · RSS · No Comments

VEGA have introduced a VEGAFLEX guided wave radar level gauge (TDR) with a remote housing option. It uses a special connection cable (in three standard lengths: 2, 5 and 10m -longer lengths available) to a housing incorporating the electronics, programming and cable terminals. The process connection height is designed to be as small as possible, with a straight ‘axial’ and right-angled plug on each end of the connecting cable allowing the most suitable orientation and enabling the unit to be installed in confined spaces.

 

This version (with rod or cable electrodes) is ideal for applications such as; restricted clearance or low head-room on small vessels and bridles, where housings may be damaged (e.g. mobile tankers), if process vibration is anticipated, ‘ambient’ housing temperatures up to 100°C, or even where sensor electronics are in high radioactive areas. This new version has ATEX Gas Ex certification, standard features include: FDT/DTM, 4-20mA and HART protocol (Profibus and F options), integral device data-logging, backlit display and programmer, as with all VEGA plics transmitters. For more information contact VEGA sales on 01444 870055, or  info@uk.vega.com

Flex%20remote2 VEGA TDR gets remote housing

Top of page
Level Measurement | About VEGA UK | News and Events | Technologies | Case Studies | Product Search | Downloads | Services | Contact | VEGA Worldwide | Site Map
VEGAPULS Radar | VEGAFLEX Guided Microwave | VEGASON Ultrasonic | VEGACAP Capacitive | VEGABAR 6072 Hydrostatic | VEGA OHMART
Nucleonic | VEGAVIB Vibration Solids | VEGASWING Vibration Liquids | VEGAKON Conductive | VEGABAR Process Pressure | VEGADIF Differential Pressure | VEGACOMMS Digital Communications
Copyright 2006 © VEGA Control Ltd. All Rights Reserved - www.vegacontrols.co.uk - level measurementand pressure switch controls | InternetMarketing, Web Design By Fresh Egg
Registered Office: Kendal house, Victoria Way Burgess Hill West Sussex RH15 9NF Reg No. 1630396 England.